RT-PCR Detection System

X960 Real-Time PCR system is a high-performance benchtop instrument giving you greater control of your experiment data. It delivers reliability, sensitivity,and accuracy, which is optimized to enable the broadest range of quantitative PCR applications

Advantage

1

Innovative Optical Design

The detection system is equiped with
LED light source and high resolution CCD.
The optical filter sets are designed to maximize fluorescence detection for specific
dyes in specific channels

2

Precise Temperature Control

Two independent temperature control mode- block and tube, maximize control flexibility.
Excellent temperature uniformity limits the variation between wells, ensuring the
accuracy of low copy sample

3

Humanization Design

The machine can be connected with PC through WI-FI or LAN. The software allows you to manage and monitor several detection system from your computer.

Instrument Performance Indicators

Description Specification
Bits:  Windows XP/VISTA/Windows 7 
Minimum Memory:  32/64 
Leon Rogol 512M 
Display Unit:  256MB 
CPU:  Pentium IV 1.6GHZ or higher 
Overall Dimensions:  590mm (L)*442mm (W)*285mm (H) 
Weight 28.7kg
Connection Pattern:  LAN WIFI 
Power Supply:  AC 220V 50HZ/60HZ 
Input Power:  1000VA 
Fuse: AC 250V 10A 
Sample Capacity:  96 holes x 0.2ml 
Light Source:  Ultrahigh-luminance color mono-LED 
Detector:  High-sensitivity refrigerator CCD 
Dynamic Testing Range:  10-100000000000 
Minimum Testing Template:  Single copy 
Reaction Volume:  15μl-100μl 
Fluorescence Excitation Wavelength:   470nm-612nm 
Fluorescence Detection Wavelength:  525nm-678nm 
Fluorescein and Dye Detected:  Channel 1:FAM, SYBR
Channel 2:VIC, HEX, JOE, TET, TAMRA
Channel 3:ROX, TEXRAD
Channel 4:CY5 
Channel 5:Reserved for user
Temperature Range:  0℃~100℃ 
Heating Rate:  ≥5℃/s (45℃—99℃) 
Cooling Rate:  ≥5℃/s (45℃—99℃) 
Temperature Control Uniformity:  At constant 95 ℃ within 10s:±0.4℃
At constant 55 ℃ within 10s:±0.4℃ 
Temperature Accuracy:  ≤±0.1 ℃( 45 ℃≤T≤95 ℃)
Gradient Temperature Width:  1℃—30℃ 
Gradient Temperature Range:  30℃—100℃ 
Heated Lid Temperature Range:  (Rt +2℃) —110℃ 
Temperature Control Mode:  Semi-conductor thermoelectric module 
Gradient Temperature Range:  Semi-conductor thermoelectric module 
Temperature Control Programming: Max. 999 cycles 
Special Functions:  Threshold analysis, dissolution curve analysis, grade, and customized parameters
Showing entries (filtered from total entries)

Item List

Price: Please contact us

Description Quantity
PCR Automatic Instrument (96 Channel) 1 Unit
Automatic Extraction Instrument (32 Channel)
(370mm x 350 mm x 380mm)
1 Unit
Buy Now

Contacts

Email: medical_sales@wiseyes.net
Phone: +60 137332735 (Ms.Kong)

Address

7th Floor, Wisma Perkeso,
No. 155, Jalan Tun Razak,
50400 Kuala Lumpur.
Wilayah Persekutuan, Malaysia.